Cannulated Screws
6.5mm
Indicated for Sub-capital Femoral Neck Fractures, Tibial Plateau Fractures, Proximal Humerus Fractures, Ankle Arthrodesis, Intercondylar Fractures of the Distal Femur, Sacro-iliac Disruptions, Sub-talar Arthrodesis, and Distal Tibial fractures.
Features
- Cancellous screws with 20mm thread length
- 3.2mm Guide wire to prevent diversion from desired placement path
- Extensive size range provides multiple applications
- Self-drilling self-tapping design reduces operative time and eliminates the possibility of drill breakage
- Sterile packaged implants for assured implant quality, sterility and traceability
- Titanium Alloy for strength and biocompatibility
- Head holding screwdriver and reverse cutting flutes for easy removal
7.3mm
Indicated for Sub-capital Femoral Neck Fractures, Tibial Plateau Fractures, Proximal Humerus Fractures, Ankle Arthrodesis, Intercondylar Fractures of the Distal Femur, Sacro-iliac Disruptions, Sub-talar Arthrodesis, and Distal Tibial fractures.
Features
- Deep cancellous threads provides superior back out resistance
- 3.2mm Guide wire prevents diversion from desired placement path
- Extensive size range provides multiple applications
- 16 and 32mm thread lengths provide improved biomechanical fixation options
- Self-drilling self-tapping design reduces operative time and eliminates the possibility of drill breakage
- Combined instrument and implant case for easy implant and instrument identification
- Titanium Alloy for strength and biocompatibility
- Head holding screwdriver and reverse cutting flutes for easy removal
K2 4.0mm Navicular
Indicated for Malleolar, Talus, Calcaneal and Distal Radius Fractures, and Paediatric Fractures of the long bones.
Features
- Cannulated screw with self-tapping cancellous threads
- Extensive size range for multiple applications
- Variable thread length provides improved biomechanical fixation in a variety of bone sizes
- Only a 1.2mm cannulation to prevent implant failure
- 316LVM Stainless Steel for high strength
- Simple combined implant and instrument case
K2 7.0mm
Indicated for Sub-capital Femoral Neck Fractures, Tibial Plateau Fractures, Proximal Humerus Fractures, Ankle Arthrodesis, Intercondylar Fractures of the Distal Femur, Sacro-iliac Disruptions, Sub-talar Arthrodesis, and Distal Tibial fractures.
Features
- 16mm, 32mm and fully threaded cannulated self-tapping cancellous screws
- Extensive size range and three diameters of washers for multiple applications
- Only a 2.2mm cannulation to prevent implant failure
- 316LVM Stainless Steel for high strength
- Simple combined implant and instrument case